    Corrugated Pipe Fittings

    Country
    France
    Project
    Essentials theme
    Client
    pixfort Inc
    Budget
    €500K - €1M
    Elsu Boru

    Corrugated Pipe Fittings

    Kod
    Code
    Ürün Adı
    Product Name
    Ölçü
    Measurement
    ELSK001 Birleştirme Manşonu / Straight Pipe Socket 40-50-63-75-90-110-118-160
    ELSK002 Sızdırmaz Conta / Spiral Pipe Muff 40-50-63-75-90-110-118-160
    ELSK003 Destek Parçası / Transparent Spiral Pipe Muff 40-50-63-75-90-110-118-160
    ELSK004 90° Dirsek / 90° Elbow 40-50-63-75-90-110-118-160
    ELSK005 Boru Tapası / T Elbow 40-50-63-75-90-110-118-160
    Koruma Sınıfı
    Protection Class
    TS EN 61386-22
    Min. Çalışma Sıcaklığı
    Min. Operating Temp.
    320N-Hafif-30sn-23±2
    Max. Çalışma Sıcaklığı
    Max. Operating Temp.
    1 kg/100mm/-5°C
    Yalıtım Direnci
    Insulation Resistance
    90°C
    Deney Gerilimi
    Test Voltage
    60°C
    Sıkıştırma Dayanımı
    Compression Strength
    -25°C
    Standart
    Standard
    PE
    Hammadde
    Raw Material
    Pe
    Renk Kodları
    Color Codes

    01

    02

    03

    04

    05

    06

    07

    Infrastructure Electrical Installation Pipes

    The TS EN 61386-24 standard describes underground pipe systems for electrical installations. The standard does not include descriptions such as the type, shape, raw material, inner and outer diameter, and wall thickness of the pipe. This standard shows the performance criteria required for the pipes to operate safely and for a long time under suitable environmental conditions. The standard mentions mechanical tests for the part of the pipe that remains underground. These are tests that describe the soil force that the pipe will bear on and the resistance to impacts it may receive. Flame spreading properties are not mentioned in pipes laid underground. Flexible coil-wound pipes are suitable for works on rough terrain, environmental lighting infrastructures, etc. and are suitable for installations buried by excavation. They are not suitable for use in horizontal drilling applications. Corrugated pipes are produced in a rigid form and are suitable for use on flat terrain. They should not be used in rough ground, etc. and the pipe should not be bent. It is recommended to use manholes or elbows in turns. Corrugated pipes have thinner walls than flexible pipes. They should be laid underground up to a maximum of 50 cm and bedding should be provided. The excavation soil should not be directly covered over the pipe and should be covered by sandblasting. Otherwise, breakage and dents in the pipe form may occur. A sealed type sleeve should be used for leak-proofing. However, it is still not suitable for use in waste water and sewage systems. The features given in the table are valid for products with our brand printed on them.