    Halogen Free Flame Retardant Pipe Fittings

    Country
    France
    Project
    Essentials theme
    Client
    pixfort Inc
    Budget
    €500K - €1M
    Elsu Boru

    Halogen Free Flame Retardant Pipe Fittings

    Kod
    Code
    Ürün Adı
    Product Name
    Ölçü
    Measurement
    ELSR101 Düz Boru Mufu / Straight Pipe Socket 16-20-25-32 mm
    ELSR201 Spiral Boru Mufu / Spiral Pipe Muff 16-20-25-32 mm
    ELSR301 Şeffaf Spiral Boru Mufu / Transparent Spiral Pipe Muff 16-20-25-32 mm
    ELSR401 90° Dirsek / 90° Elbow 16-20-25-32 mm
    ELSR501 T Dirsek / T Elbow 16-20-25-32 mm
    ELSR601 Düz Boru – Buat Rekoru / Straight Pipe – Junction Box Record 16-20-25-32 mm
    ELSR701 Spiral Boru – Buat Rekoru / Spiral Pipe – Junction Box Record 16-20-25-32 mm
    ELSR801 Geçmeli Tip Antigron Kroşe Kapaklı / Snap Type Antigron Crochet Cover 16-20-25-32 mm
    ELSR901 Geçmeli Tip Antigron Kroşe (Ay) / Interkaced Type Antigron Croched (Moon) 16-20-25-32 mm
    ELSR1001 Dübelli Kroşe / Doweled Crochet 16-20-25-32 mm
    ELSR1001 Baston Kroşe / Cane Crochet 16-20-25-32 mm
    ELSR1101 Cımbız Kroşe / Tweezer Crochet 16-20-25-32 mm
    ELSR1201 Boru Bükme Yayı / Pipe Bending Spring 16-20-25-32 mm
    ELSR1301 Dübel / Dowel 16-20-25-32 mm
    ELSR1401 110x110x74 Termoplastik Buat / 110x110x74 Thermoplastic Junction Box 6-7-8-10-12 mm
    ELSTB101 85×85 Antigron Buat / 85×85 Antigron Junction Box 110x110x74 mm
    ELSTB201 200×200 Kare Buat / Desant Type Interlocking Deep Case Cover 85×85 mm
    Koruma Sınıfı
    Protection Class
    Min. Çalışma Sıcaklığı
    Min. Operating Temp.
    -5°C
    Max. Çalışma Sıcaklığı
    Max. Operating Temp.
    60°C
    Yalıtım Direnci
    Insulation Resistance
    Deney Gerilimi
    Test Voltage
    Sıkıştırma Dayanımı
    Compression Strength
    Standart
    Standard
    TS EN 61386-21 Boru Sist.
    Hammadde
    Raw Material
    PP-PE-ABS
    Renk Kodları
    Color Codes

    01

    02

    03

    04

    05

    06

    07

    Halogen Free Flame Retardant Pipes and Fittings

    TS EN 61386-1 Flame Retardancy Test Content:

    Test Purpose: It is to determine how long the pipes in contact with flame can withstand the flame without spreading and how quickly it
    extinguishes after the flame.

    Testing Method: The pipe is exposed directly to a fire source for a certain period of time defined in the standard appropriate to its wall thickness in a closed cabin. During the test, the resistance of the pipe to flame is measured. When the pipe moves away from the flame, it should extinguish at the end of the period defined in the standard. The parts dripping from the pipe should not burn the paper placed under the test setup.

    Acceptance Criteria: The tested pipe should be able to self-extinguish shortly after the flame source is removed. The accepted spread distance and time are determined by the standard. This test is very important to understand whether the pipes are safe and how durable they are in terms of fire safety.

    Flame retardancy is a basic requirement for pipe systems, usually used in high-risk areas. However, there is a very important issue to know here. All plastics burn when exposed to fire. There is no such thing as a fireproof pipe made of PE and derivative plastics. Manufacturers produce pipes that will pass the test described in the Standard. Pipes must be tested as described in the standard and in accredited laboratories.